ISO15118 Charging loop power limits¶
Description.
Message containing the power limits, which are a result of the minimum between the static limits from the EVSE and the dynamic ones from the EV during the charging loop.
Iso15118ChargingLoopPowerLimitsUpdate¶
Topic: iso15118/gridcode. Used by ISO15118 to inform gridcode about the EV’s inverter relevant parameters in order to instantiate the curves.  | 
|||
type  | 
object  | 
||
properties  | 
|||
  | 
type  | 
string  | 
|
format  | 
uuid  | 
||
  | 
const  | 
iso15118_charging_loop_power_limits  | 
|
  | 
const  | 
update  | 
|
  | 
type  | 
object  | 
|
properties  | 
|||
  | 
type  | 
string  | 
|
  | 
type  | 
number  | 
|
  | 
type  | 
number  | 
|
  | 
type  | 
number  | 
|
  | 
type  | 
number  | 
|
  | 
type  | 
number  | 
|
  | 
type  | 
number  | 
|
Example:
{
  "id": "a504f1cd-2ae0-46cf-a93c-736a28723478",
  "name": "iso15118_charging_loop_power_limits",
  "type": "update",
  "data": {
      "evse_id": "DE*SEV*E123456789",
      "max_charge_active_power": 1300.00,
      "min_charge_active_power": 400.00,
      "max_discharge_active_power": 2760.00,
      "min_discharge_active_power": 400.00,
      "max_charge_reactive_power": 1300.00,
      "max_discharge_reactive_power": 2760.00
  }
}
Implementation
The adopted unit for the fields is Watts(W).
Implementation
At the moment the following conventions are adopted 1- “max_charge_active_power” and “max_charge_reactive_power” to be the same absolute value. 2- “max_discharge_active_power” and “max_discharge_reactive_power” to be the same absolute value.