Charging Station Parameters¶
Description.
Request for the Charging Station Parameters
CsParametersRequest¶
Topic: josev/cs. Used by josev to request the charging station parameters.  | 
||
type  | 
object  | 
|
properties  | 
||
  | 
type  | 
string  | 
format  | 
uuid  | 
|
  | 
const  | 
cs_parameters  | 
  | 
const  | 
request  | 
  | 
type  | 
object  | 
default  | 
||
Example:
{
    "id": "bd674cba-8377-4930-ba15-6a8d6e5134f2",
    "name": "cs_parameters",
    "type": "request",
    "data": {}
}
Josev shall ask once for the cs_status_and_limits every time it boots or the process restarts.
CsParametersResponse¶
Topic: cs/josev. Used by CS to provide charging station parameters to Josev.  | 
|||||||||||
type  | 
object  | 
||||||||||
properties  | 
|||||||||||
  | 
type  | 
string  | 
|||||||||
format  | 
uuid  | 
||||||||||
  | 
const  | 
cs_parameters  | 
|||||||||
  | 
const  | 
response  | 
|||||||||
  | 
type  | 
object  | 
|||||||||
properties  | 
|||||||||||
  | 
type  | 
string  | 
|||||||||
examples  | 
v1.0.1  | 
||||||||||
  | 
The hw_version schema  | 
||||||||||
type  | 
string  | 
||||||||||
examples  | 
v2.0.0  | 
||||||||||
  | 
type  | 
integer  | 
|||||||||
  | 
type  | 
array  | 
|||||||||
items  | 
anyOf  | 
type  | 
object  | 
||||||||
properties  | 
|||||||||||
  | 
type  | 
string  | 
|||||||||
examples  | 
DE*SEV*E123456789  | 
||||||||||
  | 
type  | 
boolean  | 
|||||||||
  | 
type  | 
string  | 
|||||||||
  | 
type  | 
array  | 
|||||||||
items  | 
anyOf  | 
type  | 
object  | 
||||||||
properties  | 
|||||||||||
  | 
type  | 
integer  | 
|||||||||
  | 
type  | 
object  | 
|||||||||
properties  | 
|||||||||||
  | 
type  | 
object  | 
|||||||||
properties  | 
|||||||||||
  | 
#/definitions/connector_type  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
scheduled, dynamic  | 
||||||||||
  | 
type  | 
integer  | 
|||||||||
  | 
type  | 
object  | 
|||||||||
properties  | 
|||||||||||
  | 
#/definitions/connector_type  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
scheduled, dynamic  | 
||||||||||
  | 
type  | 
object  | 
|||||||||
properties  | 
|||||||||||
  | 
#/definitions/connector_type  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
scheduled, dynamic  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
unified, separated  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
grid_following, grid_forming  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
active, passive  | 
||||||||||
  | 
type  | 
object  | 
|||||||||
properties  | 
|||||||||||
  | 
#/definitions/connector_type  | 
||||||||||
  | 
type  | 
integer  | 
|||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
scheduled, dynamic  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
unified, separated  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
grid_following, grid_forming  | 
||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
active, passive  | 
||||||||||
definitions  | 
|||||||||||
  | 
type  | 
string  | 
|||||||||
enum  | 
AC_single_phase_core, AC_three_phase_core, DC_core, DC_extended, DC_combo_core, DC_unique  | 
||||||||||
Example:
{
    "id": "bd674cba-8377-4930-ba15-6a8d6e5134f2",
    "name": "cs_parameters",
    "type": "response",
    "data": {
        "sw_version": "v1.0.1",
        "hw_version": "v2.0.0",
        "number_of_evses": 2,
        "parameters": [{
                "evse_id": "DE*SEV*E123456789",
                "connectors": [{
                        "id": 1,
                        "services": {
                            "ac": {
                                "connector_type": "AC_three_phase_core",
                                "nominal_voltage": 230,
                                "control_mode": "scheduled"
                            },
                            "ac_bpt": {
                                "connector_type": "AC_three_phase_core",
                                "control_mode": "dynamic",
                                "nominal_voltage": 230
                            },
                        }
                    },
                    {
                        "id": 2,
                        "services": {
                            "ac": {
                                "connector_type": "AC_single_phase_core",
                                "nominal_voltage": 230,
                                "control_mode": "scheduled"
                            },
                            "ac_bpt": {
                                "connector_type": "AC_single_phase_core",
                                "control_mode": "dynamic",
                                "bpt_channel": "unified",
                                "generator_mode": "grid_following",
                                "grid_island_detection_mode": "active"
                            }
                        }
                    }
                ],
                "supports_eim": true,
                "network_interface": "eth1"
            },
            {
                "evse_id": "DE*SEV*E123456790",
                "connectors": [
                {
                    "id": 1,
                    "services": {
                        "dc": {
                            "connector_type": "DC_extended"
                        },
                        "dc_bpt": {
                            "connector_type": "DC_extended",
                            "control_mode": "scheduled",
                            "bpt_channel": "separated",
                            "generator_mode": "grid_forming"
                            "grid_island_detection_mode": "passive"
                        }
                    }
                },
                {
                    "id": 2,
                    "services": {
                        "dc": {
                            "connector_type": "DC_core"
                        },
                        "dc_bpt": {
                            "connector_type": "DC_core",
                            "control_mode": "dynamic",
                            "bpt_channel": "separated",
                            "generator_mode": "grid_forming"
                            "grid_island_detection_mode": "passive"
                        }
                    }
                }
                ],
                "supports_eim": false,
                "network_interface": "eth2"
            }
        ]
    }
}
INFO.
Possible values for connector type are:
AC_single_phase_core
AC_three_phase_core
DC_core # Charging using the core pins of a IEC 62196-2 Type 1 or Type 2 connector
DC_extended # Charging using the extended and dedicated pins of a IEC 62196-3 CCS Type 1 or Type 2 connector
- DC_combo_core # Charging using the core pins of a IEC 62196-3 CCS Type 1 or Type 2 connector.
 This only works between a CCS Socket (EV side) and a Type 1/2 plug (EVSE side), because the CCS Type 1/2 plug does not have core pins for power transfer.
DC_unique # Charging using a custom/dedicated DC coupler
Possible values for the optional control mode type are (only relevant for ISO 15118-20):
scheduled # The EV computes and decices to follow a power profile schedule
- dynamic # The EVSE defines a one-off setpoint/target over time,
 which can be updated with a high frequency
Possible values for the optional bpt channel type are (only relevant for ISO 15118-20):
unified # The EVSE does BPT (Bidirectional Power Transfer) using the same wires as for charging
separated # The EVSE does BPT using dedicated wires for it
Possible values for generator mode type are:
grid_following
grid_forming
Possible values for the optional grid islanding detection mode type are (only relevant for ISO 15118-20):
active
passive