ISO15118 Charging loop power limits¶
Description.
Message containing the power limits, which are a result of the minimum between the static limits from the EVSE and the dynamic ones from the EV during the charging loop.
Iso15118ChargingLoopPowerLimitsUpdate¶
Topic: iso15118/gridcode. Used by ISO15118 to inform gridcode about the EV’s inverter relevant parameters in order to instantiate the curves. |
|||
type |
object |
||
properties |
|||
|
type |
string |
|
format |
uuid |
||
|
const |
iso15118_charging_loop_power_limits |
|
|
const |
update |
|
|
type |
object |
|
properties |
|||
|
type |
string |
|
|
type |
number |
|
|
type |
number |
|
|
type |
number |
|
|
type |
number |
|
|
type |
number |
|
|
type |
number |
Example:
{
"id": "a504f1cd-2ae0-46cf-a93c-736a28723478",
"name": "iso15118_charging_loop_power_limits",
"type": "update",
"data": {
"evse_id": "DE*SEV*E123456789",
"max_charge_active_power": 1300.00,
"min_charge_active_power": 400.00,
"max_discharge_active_power": 2760.00,
"min_discharge_active_power": 400.00,
"max_charge_reactive_power": 1300.00,
"max_discharge_reactive_power": 2760.00
}
}
Implementation
The adopted unit for the fields is Watts(W).
Implementation
At the moment the following conventions are adopted 1- “max_charge_active_power” and “max_charge_reactive_power” to be the same absolute value. 2- “max_discharge_active_power” and “max_discharge_reactive_power” to be the same absolute value.